Where it goes
A hydrophilic waterstop is fixed along a construction joint, such as the joint between a basement slab and wall or between two pours of a water tank wall. It swells when wet and presses against the concrete to seal the joint.
Prepare the surface
Clean the joint face of laitance, dust and loose material. The surface should be sound, reasonably flat and free of standing water or oil so the strip can bond.
Fix the strip
Place the strip continuously along the joint, centred in the wall thickness and fixed as the manufacturer directs, with adhesive or mechanical fixings. Butt the ends tightly and overlap or join them as per the data sheet.
Concrete cover
Keep adequate concrete cover on both sides of the strip so it can swell against solid concrete. Compact the next pour well around it so there are no voids.
Protect from early wetting
Do not leave the strip exposed to rain or water for long before concreting, because early swelling reduces its sealing effect. Cover it if the pour is delayed.
Waterstop plus admixture
Waterstops treat the joint; waterproofing admixtures reduce permeability of the concrete itself. Many below-ground structures use both. See Swell Bar waterstop and TAC 07, and the comparison in hydrophilic vs PVC waterstop.